• Biomedical Waste Shredder, Biomedical Waste Sterilizer, Sterilizer Autoclave, Infectious Waste Sterilizer, Autoclave Shredder

Biomedical Waste Steam Sterilizer Infectious Waste Autoclave Shredder

Our MRWS(Medical Waste Sterilizer Shredder) series integrated autoclave with shredder, is an ideal solution for hospitals and healthcare centers to dispose of infectious medical waste. The machine is fully automated and easy to operate. The sterilization equipment and shredder are enclosed in one sealed vessel. It is also very compact, including automatic lifter, dumper, optional steam generator, sterilizer, shredder, etc.

  • Product Description
  • Technical Parameters
  • Video

Biomedical Waste Steam Sterilizer Infectious Waste Autoclave Shredder Description:
Our MRWS(Medical Waste Sterilizer Shredder) series integrated infectious waste autoclave shredder, is an ideal solution for hospitals and healthcare centers to dispose of infectious medical waste. The machine is fully automated and easy to operate. The sterilization equipment and shredder are enclosed in one sealed vessel. integrated infectious waste autoclave shredder is also very compact, including an automatic lifter, dumper, optional steam generator, sterilizer, shredder, etc.

 

Biomedical Waste Steam Sterilizer Infectious Waste Autoclave Shredder Process:

Medical Waste Autoclave Shredder Treatment System Process

Loading: After the material is fed, the chamber is closed by filling the material elevator;
Tearing: The gear motor drives the blade shaft to rotate in the opposite direction, using cutting, shredding, extrusion, and crushing processes to crush and process materials, and synchronously achieve preliminary disinfection of waste;
Vacuum: Start the vacuum pump to evacuate the internal chamber, while maintaining the set pressure and temperature in the interlayer to ensure effective operation of the drying chamber;
Heating: Inject steam into the chamber by intermittently opening the exhaust valve to start the heating program;
Sterilization: Start timing after reaching the set sterilization temperature, control the intake valve through the temperature and pressure inside the chamber, and maintain the common chamber within the sterilization temperature range;
Cooling: After sterilization is completed, inject coolant into the inner cavity to lower it to the set temperature;
Discharge: Open the bottom discharge valve to discharge the water in the chamber, and enter the drying stage after the pressure drops to the set value;
Unloading: Open the material bottom department and unload the processed material to the transfer vehicle through the reverse valve, completing the entire process.

Medical Waste Disposal, Hospital Waste Disposal, Medical Waste Sterilizer Shredder, Integrated Sterilizer With Shredder

Biomedical Waste Steam Sterilizer Infectious Waste Autoclave Shredder Features:
1. Easy, safe, efficient, labor-saving and environmental-friendly, The biggest advantage is the low height and requirements for construction on site.
2. Green process without hazardous emissions, chemical-free and NO radiation
3. On-site treatment: avoid the risk of secondary infection
4. Advanced technology against chloride ion corrosion in medical waste
5. Advanced odor control technology ensures comfortable working ambient
6. Easy to maintain: patented technology of easily disassembled shredder largely shortens the maintenance and blade changing time.
7. Optional remote monitoring and recording system. Staffs are able to observe and control the live process in the office
8. Vessels are made of 316L stainless steel. Sterilizing and shredding the waste within a single vessel. The powerful crashing blades reduce the volume of waste down to 20%. During the exhaust stage, the Valve is opening and the steam is flowing out through the biofilter.
9. Capacity: 500L-5000L
10. Working flow: Loading-Shredding-Vacuum-Heating-Sterilization-Cooling-Exhaust-Uninstall

Infectious Waste Autoclave Shredder, Biomedical Waste Shredder, Biomedical Waste Sterilizer, Sterilizer Autoclave, Autoclave Shredder, disposal of infectious waste flow chart
Biomedical Waste Steam Sterilizer Infectious Waste Autoclave Shredder Standard Configuration
The sterilizer system is designed with integrated automation. The core module adopts high-temperature and high-pressure steam/chemical gas sterilization, and the built-in shredder ensures the security of medical data. The PLC control cabinet (including touch screen and micro printer) realizes real-time parameter monitoring and electronic record export; Automatic elevators, tilting devices, and vacuum pumps improve operational efficiency and sterilization quality, maintain the platform in compliance with OSHA standards, and optimize space utilization with stainless steel sterilization baskets and trays. The system complies with GMP and ISO 13485 standards and is suitable for high sterile scenarios such as surgical instruments and culture media, meeting the comprehensive needs of medical, pharmaceutical, and laboratory industries for efficiency, safety, and compliance.

 

Optional Configuration
•Steam boiler/steam generator
•Medical waste container
•Sharps container
•Wash unit (for the container)

 

Related equipment:

Leave a Reply

Your email address will not be published. Required fields are marked *

Model WRMS-800 WRMS-2000
Volume 0.8 2
Feeding bin volume 0.3 0.5
Receiving bin volume 0.09 0.35
Processing capacitykg/cycle 22.5-27 50-105
Overall sizeL*W*Hmm 2460*1820*1940(2640) 2890*3450*3300(4000)
Load capacity (T) 2 5
Powerkw 14+40 26.5+60

Video

Products List