• clinical waste management, clinic waste treatment, disposal of clinical waste, clinical waste disposal, medical waste disposal
  • clinical waste management, clinic waste treatment, disposal of clinical waste, clinical waste disposal, medical waste disposal
  • clinical waste management, clinic waste treatment, disposal of clinical waste, clinical waste disposal, medical waste disposal

Animal Clinic Waste Treatment Clinical Waste Management

Nowadays, keeping pets has become the norm, and with it all kinds of animal clinics have sprung up, while the medical waste generated by animal clinics is often easy to ignore. “Compared with household waste, medical animal clinic waste contains a large number of pathogenic microorganisms, parasites and other infectious, toxic and harmful substances, which can easily cause environmental pollution and human health hazards, and even become the source of epidemic disease epidemics.” Animal clinics are without medical wastewater treatment facilities, medical wastewater is directly discharged without harmless treatment; medical waste is illegally stored in the clinic (more than 48 hours, and in some cases up to tens of days). “In the invisible corner, this part of the ‘special waste’ is so handled that it is worrying.” It is therefore essential that animal clinic waste is rendered harmless.

  • Product Description
  • Technical Parameters
  • Video

Animal Clinic Waste Treatment Clinical Waste Management Description:
Animal clinical waste management is primarily applicable to a wide range of applications in dental, veterinary and small clinics, hospitals and operating rooms (OR). WRMS series horizontal medical clinical waste management animal clinic waste treatment is newly developed and produced by our company. Medical hazardous waste autoclave shredder is widely used in hospitals, clinics, health centers and dentists, etc. It meets the standard of GB150-2011《Pressure Vessel》and TSG R0004-2009《Pressure Vessel Safety Rules》Crushing, sterilization and drying can be done in only one autoclave, thus avoiding second pollution. Animal clinical waste management saves space. And can greatly reduce the costs of packaging, transportation and burying.

Why do we need animal clinic waste treatment?
Nowadays, keeping pets has become the norm, and with it all kinds of animal clinics have sprung up, while the medical waste generated by animal clinics is often easy to ignore. “Compared with household waste, medical animal clinic waste contains a large number of pathogenic microorganisms, parasites and other infectious, toxic and harmful substances, which can easily cause environmental pollution and human health hazards, and even become the source of epidemic disease epidemics.” Animal clinics are without medical wastewater treatment facilities, medical wastewater is directly discharged without harmless treatment; medical waste is illegally stored in the clinic (more than 48 hours, and in some cases up to tens of days). “In the invisible corner, this part of the ‘special waste’ is so handled that it is worrying.” It is therefore essential that animal clinic waste is rendered harmless.

Animal Clinic Waste Treatment Clinical Waste Management Technical Advantages:
For the convenience of the user, this medical waste autoclave adopts a built-in electric steam generator to produce steam as sterilization medium, automatic water supply and water level protecting system.
The feeding port is on the top of the machine with an electric sliding door which is easy for loading medical waste.
This horizontal medical hazardous waste autoclave shredder can ensure thorough shredding, sterilization and drying within 90 minutes.

Biomedical Waste Shredder, Medical Waste Sterilizer Shredder, Drug Shredder, Pharma Shredder

Animal Clinic Waste Treatment Clinical Waste Management Autoclave Shredder Structure & Characteristics:
1. The chamber is a vertical pressure vessel with a jacket, good for pre-heating, drying and continuous operation. It is made of stainless steel SUS304. The inside surface is mechanically polished. smooth and with no blind angle, can meet GMP standards.

2. Feeding port is on the top of the machine with an electric sliding door sealed with a gasket. The pneumatic lifting discharge door, which is safe and reliable, is on the bottom.

3. Lever-type promotion and demotion unloading gate which is painted with Teflon. Additional manual locking systems will make it much safer.

4. Chamber and jacket have ports for temperature and pressure sensors.

5. Pipe system contains a water pump, water level controller, vacuum pump, safety valve, angle valve, filter, non-return valve, steam trap and pressure controller.

 

Double-shaft Medical Animal Clinic Waste Shredder System
1. The waste disposal machine adopts a medium load shear type for crushing.

Double shaft medical hazardous waste shredder system

2. Horizontal medical hazardous waste shredder is equipped with a single motor reducer by a pair of gear wheels to drive a pair of knife axles to run simultaneously to shred. This low-speed, large torque system is strong and stable to shred all medical waste including, fabric, rubber, plastic, paper, glass, and a small piece of metal.

4. Autoclave with shredder equipped with heavy alloy blade, not only has strength and hardness but also has the function of automatic reversal protection when meeting unbreakable materials, which can efficiently complete the crushing work of complex medical waste at a low cost.

5. The animal clinical waste shredding system can crush medical waste containing metal products, glass products, plastic products, rubber and textiles, showing users satisfactory adaptability and tolerance.

 

Water supply & vacuum system
1. Water supply system is composed of a pump, level controller, angle valve, non-return valve, etc. The user connects the water to the pump, the system starts working automatically. When the water reaches the set level, the electric heater starts working to produce steam. When the steam temperature reaches a set degree, the autoclave starts sterilization for shredded waste.

2. Vacuum system is composed of a vacuum pump, water separator, non-return valve, vacuum valve and water pipe. This is for removing wet and hot steam from the chamber after sterilization for cooling and drying.

Control System
1. The horizontal medical hazardous waste autoclave shredder adopts PLC (Siemens)+HMI (Touch scream) for controlling and operating with three degrees of password for protection. All data can be saved or to be real-time printed.

Autoclave With Shredder Control System

Autoclave With Shredder PLC Control System

2. The horizontal medical hazardous waste autoclave shredder has the control and protection functions of temperature, pressure, liquid level, time and other system operating parameters in the sterilization operation stage, which can ensure the best sterilization effect of medical waste after crushing.

Autoclave With Shredder Printers

Autoclave With Shredder Printers

 

Animal Clinic Waste Treatment Clinical Waste Management Autoclave Shredder Procedure:
Medical waste into the cavity from the top of the door seal after the full top seal the door is closed and locked, and the operator has to run one machine preset sound processing program, the program is run as follows:

Medical Waste Shredder With Sterilizer Process

1. Loading: Start the machine, open the feeding port at the top, and feed medical waste of about 80 liters. Close the door and confirm. And manually close the lock of the unloading port at the bottom.

2. Shredding: Start double shaft shredding system to shred medical waste. At the same time, supply pure water into the jacket to set the level. Start the electric heater. PTC heating system of discharging port at the bottom also Temperatureof134 ℃ ~ 138℃..

3. Vacuum: Vacuum the inner cavity of the sterilizer, enter steam operation, repeat several times (generally take three times), then vacuum again, after the pressure of the inner cavity reaches the lower limit of pulsation, the program turns into the heating stage. After this stage, the cold air exclusion rate of the inner cavity can reach more than 99% to ensure that there are no dead corners in the inner cavity and that sterilization is qualified. (The set parameters are: pulsation three times, pulsation upper and lower limits are. (The parameters can be adjusted).

4. Heating: Steam enters the inner chamber through the sterilizer sandwich and heats the waste, while the inner chamber trap opens intermittently to discharge the water produced by steam condensation. When the temperature of the inner chamber reaches the set value (generally taken as 134°C), the program moves to the sterilization phase.

5. Sterilization: When the pressure in the jacket reaches a set value, Open connecting valve. Steam enters the chamber from the jacket. When the temperature in the chamber REACHES 134℃ ~ 138℃, Keep for 4 ~ 10 minutes.

Vertical Medical Hazardous Waste Shredder

6. Exhaust: The bottom outlet valve opens to discharge the water and exhaust gas in the outlet chamber, and the pressure in the chamber drops to the set value and enters the program branch drying stage.

7. Dry: The vacuum pump opens to make the inner cavity evacuate, while the sandwich maintains a certain pressure and temperature to play the role of drying, the inner cavity drying time (generally needs 12-15min, in 0-99min can be set at will) to the exhaust valve and the vacuum pump close, the return valve opens to make the inner cavity back to zero pressure. When the pressure in the inner cavity rises to -10KPa, the program turns to the end stage.

8. Uninstall: Open the door at the bottom of the material and unload the material to the material transfer car.

 

Related equipment:

Leave a Reply

Your email address will not be published. Required fields are marked *

Model WRMS-80 WRMS-80 Plus
Treatment Capacity 10-12kgs/circle 60-100kgs/circle
Power supply 380V, 50HZ, three phase(standard)
220V, 60HZ, three phase/480 VAC, 60 Hz three phase optional
according to the customer’s requirement
Designed pressure 0.29MPa
Working pressure 0.25Mpa
Vacuum -0.09MPa
Temp.tolerance ±1.0℃
Working temp Max 134℃~138℃
Overall dimension(L*W*H) 1720*890*1370mm 2200*1400*1950mm

Video

Products List